Handles pulls panic bars door hardware ada compliant locks exit devices handles pulls latches and other operable parts on doors shall comply operable parts of such hardware shall be 34 inches minimum and 48 inches maximum above the finish floor or ground.
Ada compliant door hardware requirements.
Of force to operate.
Minimum number 206 4 doors doorways and gates 206 5 and 404 automatic and power assisted doors and gates 404 3 common questions.
5 pounds 22 2 n maximum.
Entrances doors and gates.
Hardware required for accessible door passage shall be mounted no higher than 48 in 1220 mm above finished floor.
Lever handles and some other types comply with this requirement.
It must also be operable with one hand and without tight grasping pinching or twisting of the wrist.
A minimum of 10 inches is required from the bottom of pull handle to the finished floor on the corridor side.
The push side of all swinging manual doors as well as gates must have a smooth surface on the bottom of the door a minimum 10 inches in height from the finished floor or ground.
In addition to section 309 4 another section speaks of the amount of force when opening doors and gates.
Interior hinged doors and gates.
Sliding or folding doors.
5 pounds 22 2 n.
Door opening and closing requirements door and gate opening force.
If a door has a closer then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees the door will take at least 3 seconds to move to a point 3 in 75 mm from the latch measured to the leading edge of the door.
Door hardware must not require more than 5 lbs.
To guarantee an interior door with a closer can maintain 5 pounds or less opening force requires a door closer that will adjust down to size 1.
The ada says 1.
A common violation of the door standards is found in the smooth surface requirements of section 404 2 10.
Also the smooth surface must be the full width of the door.
Section 404 2 9 covers two types of doors.
Exterior fire doors must have the minimum opening force allowed by your local fire code usually 7 5 lbf.