For example for an 8 in.
2 hr fire rated brick wall.
Accepts no responsibility for proper application of the rated wall assembly above or responsibility for the construction of such assemblies.
203 mm limestone aggregate concrete masonry wall with a maximum control joint width of in.
U902 consists of a drainage wall with brick veneer and concrete masonry units and has a 4 hour rating.
Westbrook block is a proud producer of underwriters laboratories ul approved fire rated cmu in both light weight and normal weight densities in 2 3 and 4 hour configurations.
The american society for testing and materials and underwriters laboratory both have specifications for.
The fire resistance rating of concrete masonry walls depends on the type of aggregate used in the units.
Use steel studs and two layers of 1 2 inch type c drywall on each side of the studs for a two hour fire rating on an interior wall.
Concrete masonry unit.
As an example a wall with a fire resistance period of 2 hours and 25 minutes may only attain a fire resistance rating of 2 hours.
Use special fiberglass rated for use in firewalls.
Elements of buildings the fire resistance rating classifies the ability of an assembly to confine and isolate fire within a zone comprised of fire resistance rated walls ceiling and floor assemblies.
13 mm a 1 in.
It is also referred to as a fire rating fire resistance classification or hourly rating.
25 mm thickness measured perpendicular to the face of the wall of ceramic fiber in the joint can be used in walls with fire resistance ratings up to 3 hours while a 2 in.
The ratings relate to fire tests designed to determine how quickly fire can raise the temperature to unacceptable levels.
A 1 hour fire rating and a 2 veneer with a 1 air space for a 2 hour fire rating.
Mount a 1 1 2 inch fiberglass barrier inside the studs.
A fire resistance rating is based on a fire resistance period and usually given in half hour or hourly increments.
Usg provides resources here for our ul wall assemblies for seamless integration into any construction project.
These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies.
Figure 2 anchored brick veneer.
For further information on fire resistance of brick see technical notes 16.
Table 720 1 2 of the international building code item numbers 1 1 1 through 1 2 1 can also be used to determine the minimum equivalent thickness for brick to achieve a fire rating from 1 to 4 hours.
These blocks while allowing for safe means of egress and fire rating should no longer be looked at as just normal grey cmu.
2 hour fire rating.