13 mm a 1 in.
2 hr fire rated block wall.
203 mm limestone aggregate concrete masonry wall with a maximum control joint width of in.
Figure 3 shows the types of control joints.
Double the number of type x sheets on the wall for a simple system installed over fire resistant fiberglass insulation.
2 hour exterior wall assembly ul design no.
It is also referred to as a fire rating fire resistance classification or hourly rating.
These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies.
Linear interpolation from table 721 3 2 of the florida building code for exposed finish block mix 55 limestone 45 siliceous aggregates.
Expanded slag or pumice 4 7 4 5 4 4 4 2 4 0 3 8 3 6 3 4 3 2 3 0 2 7 2 5 2 1 1 9 1 5 a fire resistance rating between the hourly fi re resistance rating periods listed may be determined by linear in terpolation based on the equivalent thickness value of the concrete masonry unit.
2 hour interior wall assembly ul design no.
51 mm thickness can be used.
25 mm thickness measured perpendicular to the face of the wall of ceramic fiber in the joint can be used in walls with fire resistance ratings up to 3 hours while a 2 in.
Each sheet of 5 8 inch type x drywall is rated to resist fire for one hour so two layers will produce a two hour firewall.
2 52 3 80 4 78 5 60 e.
Usg provides resources here for our ul wall assemblies for seamless integration into any construction project.
Westbrook block is a proud producer of underwriters laboratories ul approved fire rated cmu in both light weight and normal weight densities in 2 3 and 4 hour configurations.
6 usg fire resistant assemblies test certification test conditions and fire and sound tested assemblies listed in this selector are based on characteristics properties and performance certificationof materials and systems obtained under controlled test conditions as set forth in the appropriate astm standard in effect at the time of test.
These blocks while allowing for safe means of egress and fire rating should no longer be looked at as just normal grey cmu.
Fire rating 1 hr.
Put two sheets together on one side or use one sheet on each side of a wall.
These listings are short summaries to serve as a.
Movement control joints in fire rated wall assemblies should also be rated.
The rated fire resistive periods for block walls can be determined by knowing this information and complying with table 721 1 2 item number 3 of the international.
A fire resistance rating is based on a fire resistance period and usually given in half hour or hourly increments.