Fire rated construction acoustical performance partition applications fire detail physical data description test no.
2 hour fire rated exterior wall assembly.
Warnock hersey fire resistance rated wall assemblies warnock hersey product listings standards products are certified against astm iso en can cgsb can ulc 1 hour fire resistive rated wall assemblies click the link above each design number below represents a james hardie 1 hour fire resistive wall assembly jh fcs 60 01.
2 hour fire resistance rated exterior wall assembly.
Finish the wall with a 1 inch coat of portland cement gypsum plaster.
Install 5 8 inch type c drywall on the interior surface and 1 2 inch gypsum sheathing on the exterior.
Use where wall is required to be rated from the exterior and interior sides.
Accepts no responsibility for proper application of the rated wall assembly above or responsibility for the construction of such assemblies.
Build a two hour exterior wall with steel studs rather than wood and special metal stud fiberglass insulation between the studs.
Installed with long dimension of sheet strength axis or face grain parallel with studs.
Base layer 5 8 inch 15 88 mm type x gypsum wallboard applied parallel to studs with 6d coated nails 1 7 8 inch 228 6 mm long 0 0915 inch 2 48 mm shank inch 6 35 mm heads 12.
Exterior wood siding min 11 32 in.
American softwood lumber standard ps 20.
Lumber shall be identified by the grade mark of a lumber grading or inspection agency that has been approved by an accreditation body that complies with the.
Elements of buildings the fire resistance rating classifies the ability of an assembly to confine and isolate fire within a zone comprised of fire resistance rated walls ceiling and floor assemblies.
Lp flameblock fire rated osb sheathing is a component of the following code compliant fire rated assemblies.
Wd stud 2 layers 5 8 sheetrock brand gypsum n a j panels firecode core outside both sides 5 8 sheetrock brand gypsum panels firecode core inside both sides 2 rows 2 x 4 24 o c base layer.
V337 2 hour interior wall assembly ul design no.
Thick 4 feet wide osb siding panel.
Fire safety caution passing a fire test in a controlled laboratory setting and or certifying or labeling a product as having a one hour two hour or any other fire resistance or protection rating and therefore as acceptable for use in certain fire rated assemblies systems does not mean that either a particular assembly system incorporating the product or any given piece of the product.
Thick 4 ft wide wood plywood siding panels or 7 16 in.
Descriptions of successfully tested i joist floor as.
2 hour exterior wall assembly ul design no.
Resistance rating for fire from the exterior face optional for 2 hr fire resistance rating for fire from interior face.